IEC 60870-5-104:2016

Telecontrol Equipment and Systems — Part 5-104: Network Access for IEC 60870-5-101 Using Standard Transport Profiles

SPEC // INSPECT: IEC 60870-5-104:2016REVIEWED: 2026-09-16
CATEGORYUtility & Grid Protocols
JURISDICTIONINTERNATIONAL
MANDATORY LEVELTECHNICAL_STANDARD
LIFECYCLE STATUSCURRENT
EXECUTIVE BRIEF SPECIFICATION PDFDISTRIBUTION LOCKED
Fail-Closed Distribution Policy: Download control is visibly disabled until Cloudflare R2 CDN upload and remote SHA-256 verification complete.
[AI // ARCHITECTURAL SUMMARY]

IEC 60870-5-104 ('IEC 104') adapts the serial IEC 101 telecontrol standard to TCP/IP Ethernet networks. Used universally across power distribution, gas pipeline, and water SCADA grids, it manages master-substation communications, Application Service Data Units (ASDUs), cyclic analog measurements, spontaneous event alarms, clock synchronizations, and command controls over TCP port 2404.

Scope & Applicability

Wide area network (WAN) telecontrol links connecting Central Dispatch SCADA systems with remote terminal units (RTUs) and distribution substations.

Non-Coverage Boundaries

Does not define internal digital substation bus mechanisms (which use IEC 61850) or North American DNP3-based implementations.

Key Clauses & Control Requirements

iec-104-apci

Application Protocol Control Information (APCI)

Four-byte control field structuring frame transmission: I-format (Information transfer with sequence counters), S-format (Supervisory acknowledgment), and U-format (Unnumbered control: STARTDT, STOPDT, TESTFR).

iec-104-asdu

Application Service Data Unit (ASDU) Profiles

Standardized data types: Single-point information (M_SP_NA_1), Measured value normalized (M_ME_NA_1), and Single command (C_SC_NA_1) with timestamping.

iec-104-sec

Cybersecurity Integration (IEC 62351-3 TLS)

Securing legacy cleartext IEC 104 sessions with mandatory TLS 1.3 encryption, mutual certificate authentication, and cryptographic session renewal.

[AUDIT // VERIFIABLE EVIDENCE CHECKLIST]

Required Regulatory & Audit Evidence Artifacts

  • [✓]RTU Point-to-Point Commissioning Signal Test Logbook
  • [✓]Network Firewall Rule Review verifying restricted TCP port 2404 routing between authorized IPs
  • [✓]Wireshark protocol dissector traces showing APCI STARTDT handshakes and ASDU traffic
[LEADERSHIP TAKEAWAY // CTO & VP OF ENGINEERING DIRECTIVE]
Legacy IEC 104 runs in cleartext without authentication by default; an attacker on the telemetry network can inject fake breaker open commands. Implement IEC 62351-3 TLS or encrypted IPsec tunnels across all utility WAN circuits.
PRIMARY SOURCES & AUTHORITY

Frequently Asked Questions

What port does IEC 60870-5-104 use?

IEC 104 uses standard IANA TCP port 2404.